Skip to content
Corrosion Coupons

Monitoring

Corrosion Coupons

Direct measurement of protection at a known surface area

Steel coupons of known surface area buried adjacent to the pipeline and connected through a test station. Because the coupon can be disconnected instantly, it gives an IR drop free potential reading and a direct measurement of current density that the pipeline itself cannot provide.

Technical Data

Specifications

Material
Same grade as the protected structure
Surface area
1, 10 or 100 cm2 to order
Types
Coupon only, or with integral reference electrode
Connection
Through test station with shorting link and shunt
Measurement
Instant off potential and coupon current density
Burial
At pipe depth, in native soil adjacent to the line

Specifications shown are indicative. Final ratings, sizes and materials are confirmed against your technical specification and the CP design calculation at enquiry stage.

Typical Applications

  • IR drop free potential measurement at critical locations
  • Current density verification against design assumptions
  • AC corrosion risk assessment on interference affected sections
  • Coating performance monitoring over time

Supply only, or supply with installation?

We quote for both. Installation by the same team that supplied the material keeps responsibility with a single agency.

Contact Us

Material Enquiry

Get this quoted against your specification

Send us the drawing, the design calculation, or simply the quantity and size required. We will revert with a firm quotation and a delivery schedule.

Speak to us directly

Amit Kumar Giri

Proprietor

+91 89611 74927Chat with us on WhatsApp

B/2/H/10, Parikshit Roy Lane, P.O. Tangra, P.S. Entally,
Kolkata - 700015, West Bengal