Skip to content

Construction

Sacrificial (Galvanic) Anode CP Systems

Magnesium and zinc anode systems for distribution networks, casings, short sections and well coated assets where an impressed current source is not practical or not required. Supply, burial and connection are carried out as a single scope.

Scope of Work

What This Service Covers

  • Magnesium anode supply, backfill preparation and burial
  • Zinc ribbon anode installation alongside the pipeline
  • Anode to pipe cable connection by thermit weld or pin brazing
  • Anode junction boxes with shunt and resistor arrangement
  • Post installation current output and potential verification

Deliverables

  • Installed galvanic anode system with tested connections
  • Anode current output records at each location
  • Structure to electrolyte potential readings
  • Installation report and as built marking

Applicable Standards

  • NACE SP0169
  • ISO 15589-1

Need this service quoted?

Send us the asset details and we will revert with a method statement and our offer.