Skip to content

Survey & Testing

Current Attenuation Test (CAT Survey)

Measurement of how the protective current decays along the pipeline. An AC signal is injected at a test point and the current is measured at intervals along the route, so that sections with deteriorated coating or an unintended current drain can be identified without excavation.

Scope of Work

What This Service Covers

  • AC signal injection at drain points and test lead points
  • Current magnitude and phase measurement at intervals along the route
  • Attenuation gradient calculation section by section
  • Coating conductance and average coating resistance assessment
  • Detection of shorted casings, foreign contacts and unintended bonds
  • Correlation with test lead point potential records

Deliverables

  • Current attenuation profile plots for each section
  • Coating conductance and coating resistance figures per section
  • Ranked list of sections requiring detailed survey or repair
  • Survey report with recommendations for further assessment

Applicable Standards

  • NACE SP0169
  • NACE SP0502
  • BS EN 13509

Need this service quoted?

Send us the asset details and we will revert with a method statement and our offer.

Send Enquiry

Contact Us

Send us your requirement

Share the line size, route length, soil conditions and the standard you work to. We will revert with a suitable design approach, the scope of work and our offer.

Speak to us directly

Amit Kumar Giri

Proprietor

+91 89611 74927Chat with us on WhatsApp

B/2/H/10, Parikshit Roy Lane, P.O. Tangra, P.S. Entally,
Kolkata - 700015, West Bengal