Skip to content

Survey & Testing

Close Interval Potential Survey (CIPS)

Continuous on and instant off potential measurement at close spacing along the pipeline. CIPS locates under protected sections, shorted casings and interference that routine annual TLP readings cannot detect.

Scope of Work

What This Service Covers

  • Synchronised current interrupter installation at all sources
  • On and instant off potential logging at 1 to 2 m intervals
  • GPS chainage correlation with pipeline alignment sheets
  • Identification of under protected and over protected sections
  • Shorted casing and foreign structure contact detection

Deliverables

  • Continuous on and off potential profile plots
  • Anomaly register with chainage and severity
  • Repair and remediation recommendations

Applicable Standards

  • NACE SP0207
  • NACE SP0169

Need this service quoted?

Send us the asset details and we will revert with a method statement and our offer.

Send Enquiry

Contact Us

Send us your requirement

Share the line size, route length, soil conditions and the standard you work to. We will revert with a suitable design approach, the scope of work and our offer.

Speak to us directly

Amit Kumar Giri

Proprietor

+91 89611 74927Chat with us on WhatsApp

B/2/H/10, Parikshit Roy Lane, P.O. Tangra, P.S. Entally,
Kolkata - 700015, West Bengal