Skip to content

Construction

Tank, Vessel & Mounded Bullet CP

Cathodic protection of above ground storage tank bottoms, underground vessels and LPG mounded storage bullets, using distributed anode arrangements and permanent reference cell grids.

Scope of Work

What This Service Covers

  • Tank bottom external CP with grid or deep well anodes
  • LPG mounded bullet CP with distributed anode arrangement
  • Underground vessel and sump protection
  • Permanent reference electrode grid installation
  • Monitoring junction boxes with individual anode shunts

Deliverables

  • Installed CP system with commissioning records
  • Reference cell grid potential map
  • Protection criteria compliance report

Applicable Standards

  • API RP 651
  • NACE SP0193
  • ISO 15589-1
  • OISD-STD-129

Need this service quoted?